Features of TiIV and ScIII behavior in oxalic acid solutions affecting the 44Ti/44Sc generating system based on anion exchange resins

N. A. Titchenkoab, B. V. Egorovaa, S. N. Kalmykovac

a Department of Chemistry, M. V. Lomonosov Moscow State University, 119991 Moscow, Russian Federation
b Institute for Nuclear Research, Russian Academy of Sciences, 117312 Moscow, Russian Federation
c A. N. Frumkin Institute of Physical Chemistry and Electrochemistry, Russian Academy of Sciences, 119071 Moscow, Russian Federation


Аннотация: Generator columns based on Dowex 1X8 anion exchange resin and TEVA extraction chromatography resin with 0.005 M H2Ox + 0.065 M HCl eluent were compared. The behavior of 44Ti and 44Sc on the resins is explained by the corresponding fractions of anionic species of TiIV and ScIII in solutions of oxalic and hydrochloric acids mixtures. A laboratory generator based on TEVA with 0.005 M H2Ox + 0.065 M HCl eluent allowed to obtain over 96% 44Sc in 3 ml of eluent with a 44Ti breakthrough of no more than 5 × 10−5%.

Ключевые слова: 44Ti, 44Sc, radionuclide generator, TEVA, Dowex 1X8, anion exchange resin, speciation in aqueous solutions.