Synchronously pumped picosecond Raman laser utilizing an LiIO3 crystal

G. G. Grigoryan, S. B. Sogomonyan


Abstract: An experimental investigation was made of a Raman laser emitting picosecond optical pulses from an LiIO3 crystal (λl = 1.143 μm), pumped synchronously by a train of pulses from a phosphate neodymium glass laser with mode self-locking (λp = 1.054 μm). The time characteristics of the Raman laser radiation were determined as a function of the mismatch of the resonator lengths. When the resonator lengths were matched, the duration of the output pulses was shortened by a factor of 7 or 8 compared with the pump pulses. In this case, the duration of the output pulses was ~ 1 ps and the energy conversion efficiency was ~ 30%.

UDC: 621.373.826 038.825.2

PACS: 42.55.Ye, 42.60.By, 42.60.Da, 42.60.Fc, 42.60.Lh, 42.65.Re