Measuring pulsed heat flux by anisotropic thermoelement

P. A. Popova, B. I. Reznikova, V. A. Sakharova, A. S. Shteinbergb

a Ioffe Institute, St. Petersburg
b N. N. Semenov Institute of Chemical Physics, Russian Academy of Sciences, Moscow

Abstract: The relationship between the electric response signal of a thermal sensor and the temperature change caused by pulsed thermal load on the working surface is established within the framework of a one-dimensional model of the anisotropic thermoelement. A signal from the gradient heat-flux sensor based on an anisotropic bismuth single crystal that occurs on a steel plate exposed in a pulsed supersonic flow is analyzed in terms of the model. The results of the heat flux calculation using the temperature sensor response are compared to the data of direct measurements.

Received: 05.08.2010


 English version:
Technical Physics Letters, 2011, 37:1, 12–14