JOURNALS // Pisma v Zhurnal Tekhnicheskoi Fiziki // Archive

Pisma v Zhurnal Tekhnicheskoi Fiziki, 2024 Volume 50, Issue 20, Pages 40–43 (Mi pjtf6800)

Distribution of temperature of outgoing flows over the cross-section for different schemes and operating modes of a counter-current vortex tube

V. N. Samokhvalov

Samara National Research University, Samara, Russia

Abstract: The difference in the temperature distribution over the cross-section of cooled and heated air flows with axial and radial arrangement of the outlets of a counter-current vortex tube has been experimentally established. With an axial arrangement of the outlets of both cooled and heated air, the temperature gradient over the cross-section of the flow depends on the ratio of the cross-sectional areas of the outlet channels. The zones of secondary vortex structures have the minimum temperature. With a radial arrangement of the outlets of both cooled and heated air, the temperature over the cross-section of the flows is equalized due to the destruction of secondary large-scale vortex structures.

Keywords: vortex tube, temperature separation, vortex structures.