RUS  ENG
Full version
JOURNALS // Zhurnal Tekhnicheskoi Fiziki // Archive

Zhurnal Tekhnicheskoi Fiziki, 2022 Volume 92, Issue 11, Pages 1745–1758 (Mi jtf7482)

Experimental instruments and technique

Comparison of back-scattering and forward-scattering methods in short range microwave imaging systems

V. V. Razeviga, A. S. Bugaevb, S. I. Ivashova

a Bauman Moscow State Technical University, Moscow, Russia
b Moscow Institute of Physics and Technology (National Research University), Dolgoprudny, Moscow Region, Russia

Abstract: Microwave imaging technique allows obtaining images of hidden objects in structures and media using microwaves. Usually in short-range microwave imaging systems, the back-scattered signal is used, when a combined transmit-receive antenna scans over a plane, forming a two-dimensional synthesized aperture, while the signal reflected from the object of observation is recorded, as a result of which a microwave hologram of the object is formed. The second option involves registering the forward-scattered signal, when the transmitting and receiving antennas are located on opposite sides of the object and scan synchronously. The purpose of this work is a theoretical and experimental comparison of these two sounding options, identifying the advantages and disadvantages of each option, taking into account the features that arise when solving various problems of microwave imaging.

Keywords: microwave holography, mivrowave image, back-scattered signal, forward-scattered signal, range resolution.

Received: 30.06.2022
Revised: 26.07.2022
Accepted: 27.07.2022

DOI: 10.21883/JTF.2022.11.53450.173-22



Bibliographic databases:


© Steklov Math. Inst. of RAS, 2026