RUS  ENG
Full version
JOURNALS // Pis'ma v Zhurnal Èksperimental'noi i Teoreticheskoi Fiziki // Archive

Pis'ma v Zh. Èksper. Teoret. Fiz., 2024 Volume 119, Issue 11, Pages 810–816 (Mi jetpl7242)

PLASMA, HYDRO- AND GAS DYNAMICS

Features of the neutralization of fast protons in a hydrocarbon pellet cloud

O. A. Bakhareva, V. Yu. Sergeev, I. A. Sharov

Peter the Great St. Petersburg Polytechnic University, St. Petersburg, 195251 Russia

Abstract: To measure the high-energy part of the energy distribution function of ions in a hot plasma using the pellet charge exchange (PCX) diagnostic, it is necessary to know the energy dependence of the fraction $F_0(E)$ of fast ions neutralized when intersecting a pellet cloud. Using experimental and calculated data on the ablation of polystyrene macroparticles (pellets) in the LHD stellarator, the function $F_0(E)$ for protons in the hydrocarbon cloud has been calculated in the energy range of $50$$1000$ keV at pitch angles $ \geqslant 70^\circ $. At energies of $50$$200$ keV, it is necessary to take into account the decrease in the flux of neutralized protons multiply intersecting the cloud. Energy losses of protons along the trajectory provide a lower bound $E > 100$ keV for the possible PCX measurements. The necessity of the control of the charge state composition and structure of the cloud limits the view area of the detector of atoms within $\pm30$ mm from the position of a pellet along the magnetic field. For this reason, the injection axis should be aligned with the observation axis of the neutral particle analyzer for the optimal geometry of PCX measurements with polystyrene pellets.

Received: 12.04.2024
Revised: 24.04.2024
Accepted: 26.04.2024

DOI: 10.31857/S1234567824110065


 English version:
Journal of Experimental and Theoretical Physics Letters, 2024, 119:11, 845–851


© Steklov Math. Inst. of RAS, 2026